Hybrid Solar inverter

IGrid SS 2k-10k
IGrid SS 2k-10k


IGrid SS 2-10KW On-grid Inverter with Energy Storage

IGrid SS is a hybrid inverter which combines solar system, AC utility, and battery power source to supply continuous power. It is suitable for remote areas where the cost of utility is too high or emergency usage when utility is not stable.

IGrid SS 2k-10k
IGrid SS 2k-10k
IGrid SS 2k-10k
IGrid SS 2k-10k
IGrid SS 2k-10k
  • Overview
  • Specifications
  • Downloads

Main Features

  • Pure sine wave output
  • Self-consumption and Feed-in to the grid
  • Programmable supply priority for PV, Battery or Grid
  • User-adjustable battery charging current suits different types of batteries
  • Programmable multiple operation modes: Grid-tie, off-grid and grid-tie with backup
  • Built-in timer for various mode of on/off operation
  • Multiple communication for USB, RS-232, Modbus and SNMP
  • Monitoring software for real-time status display and control
  • Parallel operation up to 6 units for 5KW and 10KW

 

Model IGrid SS 2KW IGrid SS Plus 3KW IGrid SS Plus 5KW IGrid SS Plus 10KW
PHASE 1-phase in/1-phase out 3-phase in/3-phase out
Max. PV INPUT POWER 2250W 4500W 10000W 14850W
Rated Output Power 2000W 3000W 5000W 10000W
Maximum Charging Power 1200 W 4800 W 9600 W
GRID-TIE OPERATION
PV INPUT (DC)
Nominal DC Voltage/Max. DC Voltage 300 VDC/350 VDC 360 VDC/500 VDC 720 VDC/900 VDC 720 VDC/900 VDC
Start-up Voltage/Initial Feeding Voltage 80 VDC/120 VDC 116 VDC/150 VDC 225 VDC/250 VDC 320 VDC/350 VDC
MPP Voltage Range 120 VDC~320 VDC 250 VDC~450 VDC 250 VDC~850 VDC 400 VDC~800 VDC
Number of MPP Trackers/
Maximum Input Current
1/1x15A 1/1x18A 2/2x10A 2/2x18.6A
GRID OUTPUT (AC)
Nominal Output Voltage 101/110/120/127 VAC 208/220/230/240 VAC 230 VAC (P-N)/
400 VAC (P-P)
Output Voltage Range 88 - 127 VAC* 184 -265 VAC* 184 - 265 VAC* per phase
Nominal Output Current 18A 13A 21A 14.5A per phase
Power Factor >0.99
EFFICIENCY
Maximum Conversion Efficiency (DC/AC) 95% 96%
European Efficiency@Vnominal 94% 95%
OFF-GRID OPERATION
AC INPUT
AC start-up Voltage/
Auto Restart Voltage
60-70 VAC/85 VAC 120-140 VAC/180 VAC 120-140 VAC per phase/
180 VAC per phase
Acceptable Input Voltage Range 80-130 VAC 170-280 VAC 170-280 VAC per phase
Max. AC Input Current 30A 40A
PV INPUT (DC)
Max. DC Voltage 350 VDC 500 VDC 900 VDC 900 VDC
MPP Voltage Range 150 VDC~320 VDC 250 VDC~450 VDC 250 VDC~850 VDC 400 VDC~800 VDC
Number of MPP Trackers/Max. Input Current 1/1x15A 1/1x18A 2/2x10A 2/2x18.6A
BATTERY Mode Output (AC)
Nominal Output Voltage 101/110/120/127 VAC 202/208/220/230/240 VAC 202/208/220/230/240 VAC 230 VAC (P-N)/400 VAC (P-P)
Output Waveform Pure Sinewave
Efficiency (DC to AC) 90% 93% 91%
HYBRID OPERATION
PV INPUT (DC)
Nominal DC Voltage/Max. DC Voltage 300 VDC/ 350 VDC 360 VDC/500 VDC 720 VDC/900 VDC 720 VDC/ 900 VDC
Start-up Voltage/Initial Feeding Voltage 80 VDC/ 120 VDC 116 VDC/ 150 VDC 225 VDC/ 250 VDC 320 VDC/ 350 VDC
MPP Voltage Range 150 VDC~320 VDC 250 VDC~450 VDC 250 VDC~ 850 VDC 400 VDC~800 VDC
Number of MPP Trackers/Max. Input Current 1/1x15A 1/1x18A 2/2x10A 2/2x18.6A
GRID OUTOUT (AC)
Nominal Output Voltage 101/110/120/127 VAC 202/208/220/230/240 VAC 202/208/220/230/240 VAC 230 VAC (P-N)/
400 VAC (P-P)
Output Voltage Range 88-127 VAC* 184-264.5 VAC* 184-264.5 VAC* per phase
Nominal Output Current 18A 13A 21A 14.5A per phase
AC INPUT
AC Start-up Voltage/Auto Restart Voltage 60-70 VAC/ 85 VAC 120-140 VAC/180 VAC 120-140 VAC per phase/ 180 VAC per phase
Acceptable Input Voltage Range 80-130 VAC 170-280 VAC 170-280 VAC per phase
Max. AC Input Current 30A 40A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage 101/110/120/127 VAC 202/208/220/230/240 VAC 202/208/220/230/240 VAC 230 VAC (P-N)/
400 VAC(P-P)
Efficiency (DC to AC) 90% 93% 91%
BATTERY& CHARGER
Nominal DC Voltage 48 VDC
Max. Charging Current Default 25A, 5A-25A 
(Adjustable)
Default 60A, 5A-100A (Adjustable) Default 60A, 10A-200A (Adjustable)
GENERAL
PHYSICAL
Dimension, D x W x H (mm) 107 x 438 x 480 204.2 x 460x 600 167.5 x 500 x 622
Net weight (kgs) 15.5 29 45
INTERFACE
Communication Port RS-232/USB RS-232/USB and CAN Interface
Intelligent Slot Optional SNMP, Modbus and AS-400 cards available
ENVIRONMENT
Humidity 0~90% RH (Non-condensing)
Operating Temperature 0 to 40 °C -10 to 55 °C
Altitude 0-1000 m**
*These figures may vary depending on different AC voltage and country requirements.
**Power derating 1% every 100m when altitude is over 1000m.
Product specifications are subject to change without further notice.